xen-devel
Re: [Xen-devel] Look for some help about Windows pv driver
 
fanliang wrote:
 Is there any body have used GPL Windows pv driver ? Or WLK tools ? After 
I installed GPL windows pv driver in my windows vm, I run WLK for a 
while, and a few minutes later, I got a BSoD with error code 
STOP0X000000F4 . Used windbg to debug, I got some call stack about  the 
system proccess .It is strange that the call stack include nothing about 
the pv driver. I'm wandering how can I fix this problem ? Many thanks if 
some one gave me some suggestions.
 
 First, have a look at 
http://msdn.microsoft.com/en-us/library/ms789516.aspx and look up the 
bugcheck code. In your case it's CRITICAL_OBJECT_TERMINATION. If you 
look at http://msdn.microsoft.com/en-us/library/ms797140.aspx you'll see 
that parameter 1 of the bugcheck tells you the object type (process or 
thread), parameter 2 points to the object, parameter 3 points to the 
process image file name and parameter 4 points to an ASCII string 
telling you what happened.
If you didn't already, then run !analyze -v inside windbg as it will 
also tell you most of this and decode some of the info for you.
  Paul
--
===============================
Paul Durrant, Software Engineer
Citrix Systems (R&D) Ltd.
First Floor, Building 101
Cambridge Science Park
Milton Road
Cambridge CB4 0FY
United Kingdom
===============================