[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [Xen-users] Xen and I/O Intensive Loads



On Wed, Aug 26, 2009 at 10:01:13AM -0600, Nick Couchman wrote:
> 
> Hi, folks, 
> The disk volume for the e-mail is on my SAN, and I've attached the FC LUN to 
> my Xen host

Does the SAN LUN perform OK from dom0 without any domUs running?

> I'm running into an issue with high I/O wait on the box (~250%) and large 
> load averages (20-40 for the 1/5/15 minute average).

Do you have iowait on dom0, or only in domU?

Try running "iostat 1" in both dom0 and domU.

Also, have you dedicated a cpu core only for dom0?

> I'm running Xen 3.2.0 on SLES 10 SP2, on a Dell PowerEdge R610 server.  The 
> FC HBA is a QLE2462, dual-channel 4Gb FC card.  Any help, hints, etc., are 
> greatly appreciated! 

You could also try updating to SLES11.

-- Pasi