 dom0 is SLES 11 SP1, domU's are paravirtualized SLES 10/11. Local physical disk partition attached to domU via "phy:" (3 SAS disks in RAID1+). 
Write throughput is %50 less than compared to write throughput to the same partition from domU. Read throughput is roughly equivalent. Tested via bonnie (e.g. with data size x2 phy mem) and "dd conv=fdatasync" where the partition is empty (no files).  The domU cpu usage is small during the tests. 
I've played around with the "Xen best practices", various memory/cpu sizes with dom0/domU, elevator=noop, but there is always a %50 difference. 
The question is how do I eliminate/find the bottleneck? I don't see any way to tweak the Xen split drivers/hypervisor in regards to block I/O. 
Thanks,
 Steve Hills
 Teradata Corporation
 steve.hills@xxxxxxxxxxxx
 
_______________________________________________
Xen-users mailing list
Xen-users@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-users 
 |