WARNING - OLD ARCHIVES

This is an archived copy of the Xen.org mailing list, which we have preserved to ensure that existing links to archives are not broken. The live archive, which contains the latest emails, can be found at http://lists.xen.org/
   
 
 
Xen 
 
Home Products Support Community News
 
   
 

xen-ia64-devel

Re: [Xen-ia64-devel] Xen/IA64 Healthiness Report -- Cset #16540

To: "Mu, Qin" <qin.mu@xxxxxxxxx>
Subject: Re: [Xen-ia64-devel] Xen/IA64 Healthiness Report -- Cset #16540
From: Alex Williamson <alex.williamson@xxxxxx>
Date: Thu, 06 Dec 2007 23:04:38 -0700
Cc: xen-ia64-devel <xen-ia64-devel@xxxxxxxxxxxxxxxxxxx>
Delivery-date: Thu, 06 Dec 2007 22:05:49 -0800
Envelope-to: www-data@xxxxxxxxxxxxxxxxxx
In-reply-to: <FC1D1B23302A22499C60C967336B2AE0015DFE79@xxxxxxxxxxxxxxxxxxxxxxxxxxxx>
List-help: <mailto:xen-ia64-devel-request@lists.xensource.com?subject=help>
List-id: Discussion of the ia64 port of Xen <xen-ia64-devel.lists.xensource.com>
List-post: <mailto:xen-ia64-devel@lists.xensource.com>
List-subscribe: <http://lists.xensource.com/cgi-bin/mailman/listinfo/xen-ia64-devel>, <mailto:xen-ia64-devel-request@lists.xensource.com?subject=subscribe>
List-unsubscribe: <http://lists.xensource.com/cgi-bin/mailman/listinfo/xen-ia64-devel>, <mailto:xen-ia64-devel-request@lists.xensource.com?subject=unsubscribe>
Organization: HP OSLO R&D
References: <FC1D1B23302A22499C60C967336B2AE0015DFE79@xxxxxxxxxxxxxxxxxxxxxxxxxxxx>
Sender: xen-ia64-devel-bounces@xxxxxxxxxxxxxxxxxxx
On Fri, 2007-12-07 at 13:53 +0800, Mu, Qin wrote:
> Xen/IA64 Healthiness Report --- Cset #16540
> 
> =================================================================
> Test Result Summary:
>       
>       In this lightly validation for Cset# 16540, neither linux nor
> window guest HVM could be created by using latest open guest firmware.
> Fortunately, switching to use Intel guest firmware with "-c" option of
> xm create command can avoid this problem. 
>       To keep the auto lightly validation workable, the combination of
> Intel guest firmware and "-c" option will be used as workaround for next
> lightly validations of new Csets until the above problem is removed.

   This was an issue with the new 16550A UART driver in QEMU.  Seems it
wasn't dropping characters when there was no client to read them, so the
GFW was probably stuck waiting for the clear to send signal.  In my
testing, either GFW works correctly with the -c option.  You can also
comment out the serial line in the domain config file to avoid the
issue.  This should be fixed on the next pull from upstream.  Thanks,

        Alex

-- 
Alex Williamson                             HP Open Source & Linux Org.


_______________________________________________
Xen-ia64-devel mailing list
Xen-ia64-devel@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-ia64-devel