WARNING - OLD ARCHIVES

This is an archived copy of the Xen.org mailing list, which we have preserved to ensure that existing links to archives are not broken. The live archive, which contains the latest emails, can be found at http://lists.xen.org/
   
 
 
Xen 
 
Home Products Support Community News
 
   
 

xen-devel

Re: [Xen-devel] default value of extra_dom0_irqs

To: <xen-devel@xxxxxxxxxxxxxxxxxxx>
Subject: Re: [Xen-devel] default value of extra_dom0_irqs
From: Andrew Cooper <andrew.cooper3@xxxxxxxxxx>
Date: Wed, 16 Nov 2011 11:10:01 +0000
Delivery-date: Wed, 16 Nov 2011 04:59:51 -0800
Envelope-to: www-data@xxxxxxxxxxxxxxxxxxx
In-reply-to: <CAJqfKE+psJxdOtLDag4x3KkVV6OysinSJbq8xYRGhv5_mEBL8w@xxxxxxxxxxxxxx>
List-help: <mailto:xen-devel-request@lists.xensource.com?subject=help>
List-id: Xen developer discussion <xen-devel.lists.xensource.com>
List-post: <mailto:xen-devel@lists.xensource.com>
List-subscribe: <http://lists.xensource.com/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=subscribe>
List-unsubscribe: <http://lists.xensource.com/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=unsubscribe>
References: <CAJqfKE+psJxdOtLDag4x3KkVV6OysinSJbq8xYRGhv5_mEBL8w@xxxxxxxxxxxxxx>
Sender: xen-devel-bounces@xxxxxxxxxxxxxxxxxxx
User-agent: Mozilla/5.0 (X11; U; Linux x86_64; en-US; rv:1.9.2.23) Gecko/20110921 Lightning/1.0b2 Thunderbird/3.1.15
On 16/11/11 03:40, Shu Wu wrote:
Hi, folks, I have a question about the default number of PIRQs of Domain 0 in Xen 4.x. I encountered a problem that cciss.ko, the HP Smart Array driver, freezed and had the system hanged at booting time. The server is HP Proliant DL385G5p and run a CentOS 5.6 dom0 with Xen 4.1.1. However everything goes well when with Xen 3.0.3 which CentOS had officially integrated in. We upgraded to Xen 4.x so as to make use of Remus.

I debugged and guessed that an IRQ of the HP RAID controller missing but could not figure out why. At last I compiled and tried and all revisions from 3.4.3 (r19995) to 4.0.0 (r20789), using a binary search method in about 10 times, and located some changes between r20142 and r20143 were the point. The code changes were:

-static unsigned int extra_dom0_irqs, extra_domU_irqs = 8;
+static unsigned int extra_dom0_irqs = 256, extra_domU_irqs = 32;
 static void __init parse_extra_guest_irqs(const char *s)
 {
     if ( isdigit(*s) )
@@ -253,9 +253,11 @@
         d->is_paused_by_controller = 1;
         atomic_inc(&d->pause_count);
 
-        d->nr_pirqs = (nr_irqs_gsi +
-                       (domid ? extra_domU_irqs :
-                        extra_dom0_irqs ?: nr_irqs_gsi));
+        if ( domid )
+            d->nr_pirqs = nr_irqs_gsi + extra_domU_irqs;
+        else
+            d->nr_pirqs = nr_irqs_gsi + extra_dom0_irqs;

         d->pirq_to_evtchn = xmalloc_array(u16, d->nr_pirqs);
         d->pirq_mask = xmalloc_array(
             unsigned long, BITS_TO_LONGS(d->nr_pirqs));


In the changes I noticed the extra_dom0_irqs, which should be 0 by default in r20142, was set to 256 in r20143, and caused default number of Dom0's nr_pirq to exceed 256. Maybe this prevent IRQ of HP RAID controller, I don't quite know about, though. After I set it to 32 (the same number as extra_guest_irqs) the cciss.ko worked well. Although I could set this value by "extra_guest_irqs=32,32" in boot param, there are still problem:
1. The argument for dom0 extra irqs, the one after the comma, is undocumented.
2. What is the reason of the magic number 256 for Dom0, and 32 for DomU in Xen 4.x by default? nr_irqs_gsi is only 16 on x64 arch, but the total nr_pirq would be more than 256. The magic number still exists in the newest code. This is bad hardcode and may cause very elusive fault for newbie user, maybe you can have a better solution.


I doubt that this is relevant.  dom0 uses the paravirtualized interface meaning it does not use real interrupts.

To start with, could you boot on Xen-4.1.1 and use the Xen debug keys on the serial console to dump the interrupt bindings ('i'), MSI state ('M') and PCI devices ('Q').  It would be useful if you could identify which PCI device the HPSA controller is, and depending on where your kernel crashes, /proc/interrupts would be very useful.