xen-devel
[Xen-devel] [PATCH] xen/blkfront: allow xenbus state transition to Closi
This situation can occur when attempting to attach a block device whose backend
is an empty physical CD-ROM driver. The backend in this case will go directly
from the Initialising state to Closing->Closed. Previously this would result in
a NULL pointer deref on info->gd (xenbus_dev_fatal does not return as a1a15ac5
seems to expect)
Signed-off-by: Ian Campbell <ian.campbell@xxxxxxxxxx>
Cc: Jeremy Fitzhardinge <jeremy@xxxxxxxx>
---
drivers/block/xen-blkfront.c | 6 ++++--
1 files changed, 4 insertions(+), 2 deletions(-)
diff --git a/drivers/block/xen-blkfront.c b/drivers/block/xen-blkfront.c
index aa0c94b..a6cbf7b 100644
--- a/drivers/block/xen-blkfront.c
+++ b/drivers/block/xen-blkfront.c
@@ -977,8 +977,10 @@ static void backend_changed(struct xenbus_device *dev,
break;
case XenbusStateClosing:
- if (info->gd == NULL)
- xenbus_dev_fatal(dev, -ENODEV, "gd is NULL");
+ if (info->gd == NULL) {
+ xenbus_frontend_closed(dev);
+ break;
+ }
bd = bdget_disk(info->gd, 0);
if (bd == NULL)
xenbus_dev_fatal(dev, -ENODEV, "bdget failed");
--
1.5.6.5