WARNING - OLD ARCHIVES

This is an archived copy of the Xen.org mailing list, which we have preserved to ensure that existing links to archives are not broken. The live archive, which contains the latest emails, can be found at http://lists.xen.org/
   
 
 
Xen 
 
Home Products Support Community News
 
   
 

xen-devel

Re: [Xen-devel] question on PV pass-through patch

To: Masroor Vettuparambil <Masroor.Vettuparambil@xxxxxxxxxxxx>
Subject: Re: [Xen-devel] question on PV pass-through patch
From: Yosuke Iwamatsu <y-iwamatsu@xxxxxxxxxxxxx>
Date: Mon, 17 Mar 2008 11:31:57 +0900
Cc: xen-devel@xxxxxxxxxxxxxxxxxxx
Delivery-date: Sun, 16 Mar 2008 19:32:27 -0700
Envelope-to: www-data@xxxxxxxxxxxxxxxxxx
In-reply-to: <78C9135A3D2ECE4B8162EBDCE82CAD7703337835@nekter>
List-help: <mailto:xen-devel-request@lists.xensource.com?subject=help>
List-id: Xen developer discussion <xen-devel.lists.xensource.com>
List-post: <mailto:xen-devel@lists.xensource.com>
List-subscribe: <http://lists.xensource.com/cgi-bin/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=subscribe>
List-unsubscribe: <http://lists.xensource.com/cgi-bin/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=unsubscribe>
References: <78C9135A3D2ECE4B8162EBDCE82CAD77032C0E38@nekter> <47D490BB.1020903@xxxxxxxxxxxxx> <78C9135A3D2ECE4B8162EBDCE82CAD7703337835@nekter>
Sender: xen-devel-bounces@xxxxxxxxxxxxxxxxxxx
User-agent: Thunderbird 2.0.0.6 (Windows/20070728)
Masroor Vettuparambil wrote:
I tried your patch with CONFIG_XEN_PCIDEV_BACKEND_VPCI.
Detached the pci on the source and attached another slot to migrated
domU on destination. Migration is happening smoothly. thanks for your work.

a minor thing I noticed is, dmesg on domU shows the following warning
during pci-detach,
WARNING: g.e. still in use!
WARNING: leaking g.e. and page still in use!

I'm not sure what this means, but it looks like something is wrong
with the disconnect procedure of pcifront/pciback.

I wonder if we can achieve a 'live' migration of direct access, ie,
without interrupting the network traffic?
Something like creating a vif(network-attach) on domU for carrying the
n/w traffic temporarily till the migration is over.
After migration, move the n/w traffic back from vif to newly
pci-attached NIC on the destination.
Any thought?

Actually I've been thinking of "passthrough domain live migration"
using a multipath-driver which combines a passthrough device and
a virtual device. Below is an idea of live migrating a domU
which has passthrough network device attached.

- First create bond0 and add the passthrough interface to it.
- Usually we use the passthrough interface (fast path).
- Before migration, attach a vif to the domU and add the vif interface
  to bond0. Then remove the passthrough inteface from bond0 and do
  pci-detach. We can migrate without network disconnection because
  the vif is now enabled (slow path).
- After migration, do pci-attach, add passthrough interface to bond0,
  and disconnect the vif interface (switch back to fast path).

I hope this method works, but I haven't have an opportunity to try it
myself yet.