WARNING - OLD ARCHIVES

This is an archived copy of the Xen.org mailing list, which we have preserved to ensure that existing links to archives are not broken. The live archive, which contains the latest emails, can be found at http://lists.xen.org/
   
 
 
Xen 
 
Home Products Support Community News
 
   
 

xen-devel

[Xen-devel] Need help figuring out why my windows pv drivers wont work w

To: "xen-devel" <xen-devel@xxxxxxxxxxxxxxxxxxx>
Subject: [Xen-devel] Need help figuring out why my windows pv drivers wont work with a 32 bit dom0...
From: "James Harper" <james.harper@xxxxxxxxxxxxxxxx>
Date: Fri, 1 Feb 2008 15:14:18 +1100
Delivery-date: Thu, 31 Jan 2008 20:14:47 -0800
Envelope-to: www-data@xxxxxxxxxxxxxxxxxx
List-help: <mailto:xen-devel-request@lists.xensource.com?subject=help>
List-id: Xen developer discussion <xen-devel.lists.xensource.com>
List-post: <mailto:xen-devel@lists.xensource.com>
List-subscribe: <http://lists.xensource.com/cgi-bin/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=subscribe>
List-unsubscribe: <http://lists.xensource.com/cgi-bin/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=unsubscribe>
Sender: xen-devel-bounces@xxxxxxxxxxxxxxxxxxx
Thread-index: AchkiOnjeDQcMReOR3CXpc44efwhug==
Thread-topic: Need help figuring out why my windows pv drivers wont work with a 32 bit dom0...
All my development up until now on the Windows PV drivers has been on an
AMD64 system with a 64 bit hypervisor, a 64 bit Dom0, and 32 or 64 bit
Windows DomU's, and that has all worked fine for me.

I've been getting reports of problems from other people, and initially
assumed (incorrectly I think) that it was a problem with Intel, but as
it turns out it appears to be a problem when Dom0 is 32 bit. When I test
with a 64 bit hypervisor and a 32 bit Dom0, the block device drivers
don't work - the first request gives a failure, and a few requests later
I get a crash. The crash is most likely because I may not be handling
failures correctly.

Anyway, I can't seem to figure out why things are breaking under vbd
when Dom0 is 32 bit. Vif works perfectly. Before some very recent
testing, I wasn't even setting the 'protocol' frontend xenstore
parameter, but I have since tried setting it to XEN_IO_PROTO_ABI_NATIVE,
XEN_IO_PROTO_ABI_X86_64 and XEN_IO_PROTO_ABI_X86_32, without any
success.

At around the time of the error, Dom0 logs "(XEN) grant_table.c:264:d0
Bad flags (0) or dom (0). (expected dom 0)", which I assume is probably
related.

Can anyone suggest what is different about the backend that I might not
be taking into account? My thoughts so far are:
. Windows is padding structures differently under 32 and 64 bits.
Strange that everything else works fine though...
. The pfn I get from MmGetMdlPfnArray (windows kernel api) isn't valid
to a 32 bit Dom0 (this function is used identically in the vif driver
though)

Any and all suggestions will be greatly appreciated!

Thanks

James