The HVM guest window resizing problem via VNC is NOT a Xen/Qemu bug.
The actual problem is the vncviewer client lacking support for the
DesktopSize VNC pseudo-encoding. Clients missing this feature don't
get notified from the server.
Looking a little around, I found two VNC clients which support this:
RealVNC and ggivnc (SVN(!) version, http://www.lysator.liu.se/~peda/ggivnc/).
Christoph
On Thursday 08 November 2007 13:49:47 Christoph Egger wrote:
> My OpenSuSE 10.2 HVM guest is 64bit.
>
> I just found a workaround:
> Close the vnc client and re-connect. Then the vnc client uses
> a larger window and I can actually see the cursor line.
>
> This behaviour looks very much to me that the vnc server code
> does not notify the client about graphic mode changes.
>
> Christoph
>
> On Tuesday 06 November 2007 17:26:45 Dave Lively wrote:
> > Hi Christoph -
> > I'm trying to reproduce the behavior you're seeing. Is your guest
> > 32- or 64-bit?
> >
> > Dave
> >
> > On 11/5/07, Christoph Egger <Christoph.Egger@xxxxxxx> wrote:
> > > An obvious bug I am seeing (but is not indicated by this certain
> > > diagnostic message) is a scrolling bug. It appears when I boot a HVM
> > > guest that uses a graphic mode (e.g. OpenSuSE 10.2). I am connected via
> > > VNC to it. I don't see the line where the cursor is. I have to blindely
> > > guess when the guest expects me to log in. After a (blind) successful
> > > login, I have to type something like 'ls' several times, until I see
> > > what I actually typed and the output of what I typed.
> > > The latest changeset I tried is 16317 and the bug is reproducable.
> > > The oldest changeset I tried so far is 16281 and this issue was
> > > reproducable there, too. I hope, that helps.
> > >
> > > Christoph
> > >
> > > On Monday 05 November 2007 17:38:24 Robert Phillips wrote:
> > > > Hi Christoph,
> > > >
> > > > What you are seeing is (I hope) just an annoying diagnostic. If you
> > > > reduce your guest log level or eliminate the gdprintk() the problem
> > > > should go away.
> > > >
> > > > The diagnostic is warning that the ioreq could not be placed in the
> > > > buffered iopage so it is being sent synchronously to qemu.
> > > > The ioreq could not be placed in the buffered iopage because it
> > > > couldn't be condensed into the (new) format.
> > > > The new format has no room to store 'count' so ioreqs with count != 1
> > > > take the slow route.
> > > >
> > > > Our experience is that the few ioreqs handled this way are far out
> > > > numbered by the condensable ioreqs
> > > > and since far more condensable ioreqs now fit in the buffered iopage
> > > > (than would fit with the old format)
> > > > the performance improvement is substantial.
> > > >
> > > > If the diagnostic is pointless and annoying, it should be eliminated.
> > > >
> > > > -- Robert Phillips
> > > >
> > > > On 11/5/07, Christoph Egger <Christoph.Egger@xxxxxxx> wrote:
> > > > > Hello Ropert!
> > > > >
> > > > > Since changeset 16285 (xen-staging), I get the following output
> > > > > when I launch
> > > > > a HVM guest and VGABios is running:
> > > > >
> > > > >
> > > > > -------------------------------------------------------------------
> > > > >-- ---- -------------- (XEN) intercept.c:172:d1 slow ioreq. type:1
> > > > > size:1 addr:0xa0000 dir:0 ptr:1
> > > > > df:0 count:16
> > > > > (XEN) intercept.c:172:d1 slow ioreq. type:1 size:1 addr:0xa0020
> > > > > dir:0 ptr:1
> > > > > df:0 count:16
> > > > > (XEN) intercept.c:172:d1 slow ioreq. type:1 size:1 addr:0xa0040
> > > > > dir:0 ptr:1
> > > > > df:0 count:16
> > > > > (XEN) intercept.c:172:d1 slow ioreq. type:1 size:1 addr:0xa0060
> > > > > dir:0 ptr:1
> > > > > df:0 count:16
> > > > > (XEN) intercept.c:172:d1 slow ioreq. type:1 size:1 addr:0xa0080
> > > > > dir:0 ptr:1
> > > > > df:0 count:16
> > > > > (XEN) intercept.c:172:d1 slow ioreq. type:1 size:1 addr:0xa00a0
> > > > > dir:0 ptr:1
> > > > > df:0 count:16
> > > > > [...]
> > > > > (XEN) intercept.c:172:d1 slow ioreq. type:1 size:1 addr:0xa1fe0
> > > > > dir:0 ptr:1
> > > > > df:0 count:16
> > > > >
> > > > > -------------------------------------------------------------------
> > > > >-- ---- -----------------
> > > > >
> > > > > This is not the full output (to keep this mail readable). The
> > > > > address output
> > > > > starts from 0xa0000 and goes to 0xa1fe0 and it always increases by
> > > > > 0x20. (So you can generate the full output yourself :)
> > > > >
> > > > > The output comes from xen/arch/x86/intercept.c, function
> > > > > hvm_buffered_io_send().
> > > > > It is this code snippet:
> > > > >
> > > > > /* Return 0 for the cases we can't deal with. */
> > > > > if ( (p->addr > 0xffffful) || p->data_is_ptr || p->df ||
> > > > > (p->count != 1) )
> > > > > {
> > > > > gdprintk(XENLOG_DEBUG, "slow ioreq. type:%d size:%"PRIu64"
> > > > > addr:0x%"
> > > > > PRIx64" dir:%d ptr:%d df:%d count:%"PRIu64"\n",
> > > > > p->type, p->size, p->addr, !!p->dir,
> > > > > !!p->data_is_ptr, !!p->df, p->count);
> > > > > return 0;
> > > > > }
> > > > >
> > > > > It looks like the problem was there before changeset 16285 but got
> > > > > uncovered
> > > > > with the addition of the debug output.
> > > > >
> > > > > Christoph
--
AMD Saxony, Dresden, Germany
Operating System Research Center
Legal Information:
AMD Saxony Limited Liability Company & Co. KG
Sitz (Geschäftsanschrift):
Wilschdorfer Landstr. 101, 01109 Dresden, Deutschland
Registergericht Dresden: HRA 4896
vertretungsberechtigter Komplementär:
AMD Saxony LLC (Sitz Wilmington, Delaware, USA)
Geschäftsführer der AMD Saxony LLC:
Dr. Hans-R. Deppe, Thomas McCoy
_______________________________________________
Xen-devel mailing list
Xen-devel@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-devel
|