xen-devel
[Xen-devel] [PATCH] Fix domain restore failure when using vncdisplay opt
Hi,
This patch fixes hvm domain restore failure when using vncdisplay option.
Thanks,
Kouya
Signed-off-by: Kouya Shimura <kouya@xxxxxxxxxxxxxx>
diff -r b28ae5f00553 tools/python/xen/xend/image.py
--- a/tools/python/xen/xend/image.py Tue Oct 23 09:26:43 2007 +0100
+++ b/tools/python/xen/xend/image.py Thu Oct 25 12:49:49 2007 +0900
@@ -409,7 +409,7 @@ class HVMImageHandler(ImageHandler):
xenopts().get_vnclisten_address())
vncdisplay = vnc_config.get('vncdisplay', 0)
ret.append('-vnc')
- ret.append("%s:%d" % (vnclisten, vncdisplay))
+ ret.append("%s:%s" % (vnclisten, vncdisplay))
if vnc_config.get('vncunused', 0):
ret.append('-vncunused')
_______________________________________________
Xen-devel mailing list
Xen-devel@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-devel
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
- [Xen-devel] [PATCH] Fix domain restore failure when using vncdisplay option,
Kouya Shimura <=
|
|
|
|
|