Re: [Xen-devel] domU - no networking
keir,
Keir Fraser schrieb:
> The transmit statistic on xen-br0 is a red herring: looking at my
> working system, the xen-br0 interface also reports 0 packets
> transmitted. Odd, but obviously therefore not an indication of trouble.
ok, good to know.
> It sounds like dom0 networking is okay for you. In cases where our
> bridging setup doesn't work, I believe it is usual for networking to
> fail completely (both dom0 and domU).
dom0 networking is fine.
i see a zombie process in the processtable:
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 2188 0.0 0.0 0 0 ? Z Oct15 0:00
[network-bridge] <defunct>
> When you boot a domU, do you have a vif called something like 'vif1.1'
> in dom0's ifconfig listing? Does this interface show any packets sent or
> received?
yes, recieved and transmit packets:
vif0.0 Link encap:Ethernet HWaddr FE:FF:FF:FF:FF:FF
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:1708751 errors:0 dropped:0 overruns:0 frame:0
TX packets:913713 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:0
RX bytes:2540344455 (2.3 GiB) TX bytes:64017546 (61.0 MiB)
peth0 also has traffic in and out.
> Does 'brctl show' show vif1.1 attached to xen-br0?
yes, it does:
root@xen300 [tmp] # brctl show
bridge name bridge id STP enabled interfaces
xen-br0 8000.feffffffffff no peth0
vif0.0
looking on a 2.0.7 bridge it looks different:
root@xen207 [tmp] # brctl show
bridge name bridge id STP enabled interfaces
xen-br0 8000.00e018526ab6 no eth0
vif2.0
maybe problems with this peth0 thing? should the bridge be attachted to
eth0 instead of peth0?
here is some dmesg output from dom0:
e1000: eth0: e1000_watchdog_task: NIC Link is Up 100 Mbps Full Duplex
device vif0.0 entered promiscuous mode
bridge: can't decode speed from peth0: 65535
device peth0 entered promiscuous mode
xen-br0: port 1(vif0.0) entering learning state
xen-br0: topology change detected, propagating
xen-br0: port 1(vif0.0) entering forwarding state
e1000: peth0: e1000_watchdog_task: NIC Link is Up 100 Mbps Full Duplex
xen-br0: port 2(peth0) entering learning state
xen-br0: topology change detected, propagating
xen-br0: port 2(peth0) entering forwarding state
the 100mbps link is ok, this machine currently runs in a test environment.
anything else i should look at to track this problem down?
--
Tschaw/2,