>>> On 2010/06/03 at 16:47, Trolle Selander <trolle.selander@xxxxxxxxx> wrote:
> Hi Nick,
>
> There's been several suggestions on how to handle multiple emulated
> serial ports in the config file, but as far as I can tell from a quick
> look at XendConfig.py, none of them have made it into the tree. It's
> still doable, however - simply create a qemu-dm "wrapper" that adds
> multiple -serial options to the qemu-dm commandline, and change the
> device_model line to point to the wrapper.
>
> -- Trolle
>
Thanks for the hint - I did this, but I'm wondering if there's a limitation on
the number of serial ports? The Qemu man page, from the most recent version of
Qemu, indicates that a maximum of 4 serial devices can be used. However,
Windows in my Xen domU only sees two of the four devices that I've attempted to
pass through, so I'm wondering if the qemu-dm version included with Xen 4 only
supports 2??
-Nick
--------
This e-mail may contain confidential and privileged material for the sole use
of the intended recipient. If this email is not intended for you, or you are
not responsible for the delivery of this message to the intended recipient,
please note that this message may contain SEAKR Engineering (SEAKR)
Privileged/Proprietary Information. In such a case, you are strictly
prohibited from downloading, photocopying, distributing or otherwise using this
message, its contents or attachments in any way. If you have received this
message in error, please notify us immediately by replying to this e-mail and
delete the message from your mailbox. Information contained in this message
that does not relate to the business of SEAKR is neither endorsed by nor
attributable to SEAKR.