xen-users
RE: [Xen-users] GPL PV Intermitent Network Problems
>
> Version shows as 0.9.11.
Pity.
Okay, please fire up DebugView and in Dom0 type "xm sysrq <domain> C".
That will cause some debug information to be dumped. Please put that in
an email to me. It should look something like:
XenPCI --> XenPci_SysrqHandler
XenPCI SysRq Value = C
XenPCI path = device/vfb/0
XenPCI backend_path = /local/domain/0/backend/vfb/82/0
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI path = device/vbd/768
XenPCI backend_path = /local/domain/0/backend/vbd/82/768
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI path = device/vbd/5632
XenPCI backend_path = /local/domain/0/backend/vbd/82/5632
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI path = device/vif/0
XenPCI backend_path = /local/domain/0/backend/vif/82/0
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI path = device/vif/1
XenPCI backend_path = /local/domain/0/backend/vif/82/1
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI path = device/vif/2
XenPCI backend_path = /local/domain/0/backend/vif/82/2
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI path = device/console/0
XenPCI backend_path = /local/domain/0/backend/console/82/0
XenPCI irq_number = 28
XenPCI irq_level = 9
XenPCI irq_vector = 1a3
XenPCI <-- XenPci_SysrqHandler
Thanks
James
_______________________________________________
Xen-users mailing list
Xen-users@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-users
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
|
|
|
|
|