On Fri, Feb 16, 2007 at 04:05:52PM +0900, Horms wrote:
> On Thu, Feb 15, 2007 at 07:01:06AM -0700, Alex Williamson wrote:
> > On Thu, 2007-02-15 at 19:30 +0900, Horms wrote:
> > > Hi Alex,
> > >
> > > I did a bit of research and it seems that the Tiger2, like the Tiger4,
> > > only has one serial port. So we can use common code for both of them,
> > > having com1=0x2f8.
> > >
> > > Tested on a Tiger 2 with the following command line, which is only
> > > needed for the linux dom0 console -- xen and linux dom0 boot messages
> > > come over serial anyway:
> > >
> > > "-- console=ttyS0"
> >
> > Hi Simon,
> >
> > Great, thanks for investigating. Once com1 is set to 0x2f8, you
> > actually shouldn't even need to specify a console= for dom0. This patch
> > will automatically set your preferred console to the xencons device:
> >
> > http://xenbits.xensource.com/ext/xen-ia64-unstable.hg?cs=81c4f90695a8
> >
> > Of course if you want to get the console mirrored on both VGA and
> > xencons as your previous cmdline did, you'll still need to specify both.
> > Thanks,
>
> It seems that if I don't set console=ttyS0 then my user-space doesn't
> know to use the serial console. But that could be more a limitation of
> my user space than anything else.
>
> Everything else seems fine.
Correction, it all works fine as you suggest.
I guess I must have had a stray console setting or something
the last time that I tested this.
--
Horms
H: http://www.vergenet.net/~horms/
W: http://www.valinux.co.jp/en/
_______________________________________________
Xen-ia64-devel mailing list
Xen-ia64-devel@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-ia64-devel
|