Re: [Xen-ia64-devel] Please try PV-on-HVM on IPF
Hi Yangkang,
You (yongkang.you) said:
The trace back message will happen when I just inserted vnif driver into
VTI, when I used 2 NICs for VTI (1 is IOEMU, the other is VNIF).
I've looked `netif_release_rx_bufs: fix me for copying receiver.'
message sometimes at vnif detaching. But I've not met domain-vti
crash.
The crashing happened if I also use IOEMU NIC for VTI domain. The VTI
vif
config should like:
vif = [ 'type=ioemu, bridge=xenbr0', '' ]
Thanks. I'll try it.
I was able to confirm this problem occurred in the same environment.
(changeset :11810 )
We continue and investigate this problem.
Sorry, the reply was delayed.
I have confirmed this problem has already corrected it as follows.
The crash doesn't happen even if IOEMU NIC is used for the VTI domain.
・xen-unstable.hg : cs 12048
・xen-ia64-unstable.hg : cs 12062
[NET] front: Clean up error handling.
This eliminates earlier work around patch for an observed crash.
However, IOEMU NIC is registered in xenwatch as VNIF.
Then the crashing happened if 'xm network-detach' is executed for IOEMU NIC.
Because IOEMU NIC is shut as VNIF.
I think that I should not register originally IOEMU NIC in xenwatch.
Because the same issue exists for x86 architecture,
I'll contribute it to the xen-devel community.
Thanks,
--
Takanori Kasai
_______________________________________________