I'll check it this evening when I'm at a working network again :(
"Jeremy Fitzhardinge" <jeremy@xxxxxxxx> wrote:
> On 10/26/2010 10:48 AM, Glauber Costa wrote:
>> On Tue, 2010-10-26 at 09:59 -0700, Jeremy Fitzhardinge wrote:
>>> If the guest domain has been suspend/resumed or migrated, then the
>>> system clock backing the pvclock clocksource may revert to a smaller
>>> value (ie, can be non-monotonic across the migration/save-restore).
>>> Make sure we zero last_value in that case so that the domain
>>> continues to see clock updates.
>>>
>>> [ I don't know if kvm needs an analogous fix or not. ]
>> After migration, save/restore, etc, we issue an ioctl where we tell
>> the host the last clock value. That (in theory) guarantees
>monotonicity.
>>
>> I am not opposed to this patch in any way, however.
>
>Thanks.
>
>HPA, do you want to take this, or shall I send it on?
>
>Thanks,
> J
--
Sent from my mobile phone. Please pardon any lack of formatting.
_______________________________________________
Xen-devel mailing list
Xen-devel@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-devel
|