WARNING - OLD ARCHIVES

This is an archived copy of the Xen.org mailing list, which we have preserved to ensure that existing links to archives are not broken. The live archive, which contains the latest emails, can be found at http://lists.xen.org/
   
 
 
Xen 
 
Home Products Support Community News
 
   
 

xen-devel

[Xen-devel] [PATCH] Test tap devices in testDeviceComplete()

To: xen-devel@xxxxxxxxxxxxxxxxxxx
Subject: [Xen-devel] [PATCH] Test tap devices in testDeviceComplete()
From: Jiri Denemark <jdenemar@xxxxxxxxxx>
Date: Tue, 10 Mar 2009 10:19:23 +0100
Delivery-date: Tue, 10 Mar 2009 02:20:13 -0700
Envelope-to: www-data@xxxxxxxxxxxxxxxxxxx
List-help: <mailto:xen-devel-request@lists.xensource.com?subject=help>
List-id: Xen developer discussion <xen-devel.lists.xensource.com>
List-post: <mailto:xen-devel@lists.xensource.com>
List-subscribe: <http://lists.xensource.com/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=subscribe>
List-unsubscribe: <http://lists.xensource.com/mailman/listinfo/xen-devel>, <mailto:xen-devel-request@lists.xensource.com?subject=unsubscribe>
Sender: xen-devel-bounces@xxxxxxxxxxxxxxxxxxx
User-agent: Mutt/1.5.18 (2008-05-17)
Hi,

XendDomainInfo.testDeviceComplete() should check block devices have shutdown
correctly but it only considers vbd class devices and ignores tap devices. The
attached patch changes testDeviceComplete() to wait for both vbd and tap
devices to be shutdown correctly.

Signed-off-by: Jiri Denemark <jdenemar@xxxxxxxxxx>

Attachment: xend-check-released-tap-devices.patch