January 8, 2007
 
Unisys ES7000/one
x86_64
16 physical processors 
32 GB RAM
xen-unstable changeset 13282 booted with dom0_mem=512M
 
Ran xm-test on dom0 (see results below).
Booted, logged into, and ran top(SLES) or task
manager(Windows) in the following domUs and domVTs (#s 2 through 6 ran simultaneously):
 
 - 32-processor 64-bit SLES10 DomU
     with 31GB memory
 
 - 4-processor 64-bit SLES10 DomU
     with 8GB memory 
 
 - 4-procesor 32-bit SLES10 DomVT
     with 2GB memory 
 
 - 4-processor 64-bit SLES10 DomVT
     with 8GB memory 
 
 - uni-processor Windows XP DomVT
     with 2GB memory 
 
 - uni-processor Windows 2003
     Server DomVT with 2GB memory 
 
 
Issues:  Dom0 panic (BUG at common.c:823) results when the 4 domVTs
(#s 3-6 above) are powered off(SLES)/shutdown(Windows).  Serial console
output attached.  I was able to successfully shutdown hvms with changeset 13205
 
Xm-test timing summary:
  Run Started : Mon, 08 Jan 2007 04:58:23 -0500
  Run Stoped  : Mon, 08 Jan 2007 05:42:56 -0500
Xm-test execution summary:
  PASS:  111
  FAIL:  1
  XPASS: 2
  XFAIL: 1
 
 
Details:
 
XFAIL: 02_network_local_ping_pos
         ping loopback
failed for size 65507. ping eth0 failed for size 65507.
 
Thanks,
Sue Krysan
Linux Systems Group
Unisys Corporation